# Demystifying VCF Automation Node Architecture & Load Balancing

DevFeed: [Demystifying VCF Automation Node Architecture & Load Balancing](<https://devfeed.tech/articles/demystifying-vcf-automation-node-architecture-load-balancing-117076.md>)

Original publisher: [Read original article](<https://blogs.vmware.com/cloud-foundation/2026/11/04/demystifying-vcf-automation-node-architecture-load-balancing/>)

Author: vmwareblogs

Published: 2026-11-04T14:00:00Z

Content type: article

Language: en

Sources: [VMware](<https://devfeed.tech/sources/vmware-blogs.md>)

Topics: [vcf automation](<https://devfeed.tech/topics/vcf-automation.md>), [Load Balancing](<https://devfeed.tech/topics/load-balancing.md>), [VMware Cloud Foundation](<https://devfeed.tech/topics/vcf-9-1.md>)

Tags: [3](<https://devfeed.tech/tags/3.md>), [architecture](<https://devfeed.tech/tags/architecture.md>), [automation](<https://devfeed.tech/tags/automation.md>), [availability](<https://devfeed.tech/tags/availability.md>), [balancing](<https://devfeed.tech/tags/balancing.md>), [cloud-infrastructure](<https://devfeed.tech/tags/cloud-infrastructure.md>), [deployment](<https://devfeed.tech/tags/deployment.md>), [external](<https://devfeed.tech/tags/external.md>), [ha](<https://devfeed.tech/tags/ha.md>), [high-availability](<https://devfeed.tech/tags/high-availability.md>), [home-page](<https://devfeed.tech/tags/home-page.md>), [ip](<https://devfeed.tech/tags/ip.md>), [layer](<https://devfeed.tech/tags/layer.md>), [load](<https://devfeed.tech/tags/load.md>), [load-balancing](<https://devfeed.tech/tags/load-balancing.md>), [native](<https://devfeed.tech/tags/native.md>), [node](<https://devfeed.tech/tags/node.md>), [vcf](<https://devfeed.tech/tags/vcf.md>), [vcf-automation](<https://devfeed.tech/tags/vcf-automation.md>), [vip](<https://devfeed.tech/tags/vip.md>), [virtual](<https://devfeed.tech/tags/virtual.md>), [vmware](<https://devfeed.tech/tags/vmware.md>)

## AI overview

A standard VCF Automation HA deployment uses three appliance VMs on one management network interface, with five node-pool IPs: three active node addresses and two reserved for upgrades, redeployments, or scale-out. It also requires two distinct FQDNs mapped to static VIPs: a public/API endpoint and a service runtime endpoint for management traffic. The embedded kube-vip and Envoy layer hosts and fails over these VIPs and routes traffic to application pods; it remains necessary even when an external load balancer or GSLB is used. In the described external-LB design, user traffic passes through the external service to the tenant-facing VIP, while SDDC Manager and VCF Operations reach the runtime VIP directly. For the stated Aria Automation 8.18.x to VCF Automation 9.x upgrade, the text specifies nine IPs: one runtime VIP, three node IPs, two buffer IPs, and three per-node VIPs, plus two FQDNs.

## Source excerpt

When deploying VCF Automation, one of the most common points of confusion on the deployment parameter screen revolves around FQDN mappings, Virtual IP (VIP) behavior, and how load balancing operates under the hood. Here is a complete breakdown structure explaining the 3-node High Availability (HA) architecture, the native load balancing layer, and how external GSLB/load ... Continued The post Demystifying VCF Automation Node Architecture & Load Balancing appeared first on VMware Blogs.