# ECGWmark: Deep Watermarking of Electrocardiogram Signals With Error-Correcting Codes

DevFeed: [ECGWmark: Deep Watermarking of Electrocardiogram Signals With Error-Correcting Codes](<https://devfeed.tech/articles/ecgwmark-deep-watermarking-of-electrocardiogram-signals-with-error-correcting-codes-93773.md>)

Original publisher: [Read original article](<https://arxiv.org/abs/2610.13357>)

Author: Kuan-Yu Chen, Kuan-Chen Wang, Yu Tsao, Jian-Jiun Ding

Published: 2026-10-21T04:00:00Z

Content type: article

Language: en

Sources: [arXiv: Cryptography and Security](<https://devfeed.tech/sources/arxiv-cryptography-and-security.md>)

Topics: [communications](<https://devfeed.tech/topics/communications.md>), [Artificial Intelligence](<https://devfeed.tech/topics/ai.md>), [payload](<https://devfeed.tech/topics/payload.md>)

Tags: [about](<https://devfeed.tech/tags/about.md>), [abstract](<https://devfeed.tech/tags/abstract.md>), [alter](<https://devfeed.tech/tags/alter.md>), [article](<https://devfeed.tech/tags/article.md>), [arxiv](<https://devfeed.tech/tags/arxiv.md>), [automated](<https://devfeed.tech/tags/automated.md>), [bridge](<https://devfeed.tech/tags/bridge.md>), [changes](<https://devfeed.tech/tags/changes.md>), [coding](<https://devfeed.tech/tags/coding.md>), [consistency](<https://devfeed.tech/tags/consistency.md>), [cpu](<https://devfeed.tech/tags/cpu.md>), [cs-cr](<https://devfeed.tech/tags/cs-cr.md>), [cs-cv](<https://devfeed.tech/tags/cs-cv.md>), [database](<https://devfeed.tech/tags/database.md>), [decoding](<https://devfeed.tech/tags/decoding.md>), [deep](<https://devfeed.tech/tags/deep.md>), [desktop](<https://devfeed.tech/tags/desktop.md>), [digital](<https://devfeed.tech/tags/digital.md>), [eess-sp](<https://devfeed.tech/tags/eess-sp.md>), [error](<https://devfeed.tech/tags/error.md>), [error-correcting-codes](<https://devfeed.tech/tags/error-correcting-codes.md>), [watermarking](<https://devfeed.tech/tags/watermarking.md>), [with](<https://devfeed.tech/tags/with.md>)

## AI overview

ECGWmark embeds metadata in single-lead ECGs while aiming to preserve arrhythmia predictions and recover complete messages after signal disruption. Its convolutional generator avoids signal quantization; a frame-by-frame detector is paired with a frozen arrhythmia classifier that penalizes diagnostic changes. Extended Hamming codes, validation-selected interleaving, and soft-decision decoding protect the payload. On MIT-BIH, bit accuracy stayed above 90% for time shifts of 10-50 samples, while transform baselines fell to chance. The coded 16-bit payload had 99.86% exact recovery on clean segments and over 90% recovery under those shifts, 10% sample deletion, and 10% packet loss. Inter-patient evaluation reported improved ventricular-beat sensitivity with preserved macro-F1. The model uses 0.56 million parameters and runs in about 15 ms per segment on a desktop CPU.

## Source excerpt

arXiv:2610.13357v3 Announce Type: replace-cross Abstract: Wearable electrocardiogram (ECG) recordings pass through multiple networks and systems before automated interpretation, making patient metadata vulnerable to loss. Digital watermarking embeds this metadata directly into the signal. However, conventional ECG watermarking methods fail under temporal desynchronization, and waveform similarity does not guarantee downstream diagnostic preservation. This article presents ECGWmark, a deep watermarking framework for single-lead ECG. A fully convolutional generator embeds the payload without signal quantization, a detector decodes the message frame by frame and verifies watermark presence, and a frozen arrhythmia classifier penalizes changes that would alter diagnostic predictions. To bridge the gap between bit accuracy and whole-message recovery, payloads are protected by extended Hamming codes, validation-selected interleaving, and soft-decision decoding. On the MIT-BIH Arrhythmia Database, ECGWmark maintains over 90\% bit accuracy under time shifts of 10 to 50 samples, where transform baselines fall to chance level. With the coding layer, the protected 16-bit payload achieves 99.86\% exact recovery on clean segments and sustains over 90\% recovery under time shifts, 10\% sample deletion, and 10\% packet loss. Inter-patient evaluation confirms improved ventricular-beat sensitivity with preserved macro-F1. Requiring only 0.56 million parameters and about 15~ms per segment on a desktop CPU, ECGWmark highlights the need to assess physiological watermarking through whole-message recovery and diagnostic consistency.