# EMG Tokenization Preserves Movement Information at a Fraction of the Bitrate

DevFeed: [EMG Tokenization Preserves Movement Information at a Fraction of the Bitrate](<https://devfeed.tech/articles/emg-tokenization-preserves-movement-information-at-a-fraction-of-the-bitrate-99644.md>)

Original publisher: [Read original article](<https://arxiv.org/abs/2610.32674>)

Author: Raul C. S\\^impetru, Amin Olamazadeh, Devon Rohlf, Vlad Cnejevici, Alessandro Del Vecchio

Published: 2026-10-26T04:00:00Z

Content type: article

Language: en

Sources: [arXiv: Machine Learning](<https://devfeed.tech/sources/arxiv-machine-learning.md>)

Topics: [communications](<https://devfeed.tech/topics/communications.md>), [Representation learning](<https://devfeed.tech/topics/representation-learning.md>), [payload](<https://devfeed.tech/topics/payload.md>), [Decoding](<https://devfeed.tech/topics/decoding.md>)

Tags: [bandwidth](<https://devfeed.tech/tags/bandwidth.md>), [benchmark](<https://devfeed.tech/tags/benchmark.md>), [cortex-m55](<https://devfeed.tech/tags/cortex-m55.md>), [cs-hc](<https://devfeed.tech/tags/cs-hc.md>), [cs-lg](<https://devfeed.tech/tags/cs-lg.md>), [decoder](<https://devfeed.tech/tags/decoder.md>), [decoding](<https://devfeed.tech/tags/decoding.md>), [eess-sp](<https://devfeed.tech/tags/eess-sp.md>), [tokenization](<https://devfeed.tech/tags/tokenization.md>), [tokenizers](<https://devfeed.tech/tags/tokenizers.md>), [wearable](<https://devfeed.tech/tags/wearable.md>)

## AI overview

In personalized, within-session 3D hand-pose decoding from 320-channel EMG in nine participants, two causal tokenizers reduced data payload while meeting a 1 mm non-inferiority criterion against continuous features. The engineered SPAR tokenizer changed mean error by +0.01 mm (95% CI −0.12 to 0.14); the learned spectral-reconstruction tokenizer changed it by +0.45 mm (0.10 to 0.82). Stored tokens reduced payload 41-fold versus raw EMG and 36-fold versus continuous SPAR. On sampled emg2pose test windows, learned-token and continuous-feature mean errors differed by less than 0.05 mm across 176 participants, including 20 unseen during training. Electrode coverage, calibration, and unseen recordings affected SPAR decoding more than quantization. Optimized SPAR generated tokens for 63 channels within 20 ms on a Cortex-M55 benchmark. The abstract supports a compact wearable-to-decoder interface, while reporting personalized within-session experiments and sampled benchmark windows rather than full benchmark evaluation.

## Source excerpt

arXiv:2610.32674v1 Announce Type: cross Abstract: Wireless electromyography (EMG) interfaces must balance electrode coverage against transmission bandwidth. Here, we show that compact EMG tokens substantially reduce payload while retaining information for three-dimensional hand-pose decoding. We evaluate two causal tokenizers fitted without pose labels: an encoder pretrained to reconstruct EMG spectra and one based on SPAR, an engineered spectral-spatial representation of neighbouring electrodes. In personalized, within-session experiments with 320-channel EMG from nine participants, we compare tokenized and continuous features using matched decoder architectures and training procedures. Averaged across decoders, tokenization changed mean error by +0.01 mm for SPAR (95% confidence interval: -0.12 to 0.14) and +0.45 mm for the learned representation (0.10 to 0.82). Both increases met a 1 mm non-inferiority criterion. Stored token arrays reduced payloads 41-fold relative to raw EMG and 36-fold relative to continuous SPAR features. On sampled windows of the public emg2pose benchmark's test partition, absolute differences in mean error between learned tokens and continuous features were below 0.05 mm across 176 participants and in the subset of 20 participants unseen during training. Electrode coverage, calibration, and unseen recordings affected SPAR decoding more than quantization did. In a computational benchmark, optimized SPAR generated tokens for 63 channels within 20 ms on a Cortex-M55 microcontroller. These findings support tokenization as a compact interface between wearable sensing and movement decoding, allowing decoders to be updated while the wearable encoder and transmitted representation remain fixed.