# Memory-Augmented Online Test-Time Adaptation for EEG Motor Imagery via Perturbation Consistency and Confidence Calibration

DevFeed: [Memory-Augmented Online Test-Time Adaptation for EEG Motor Imagery via Perturbation Consistency and Confidence Calibration](<https://devfeed.tech/articles/memory-augmented-online-test-time-adaptation-for-eeg-motor-imagery-via-perturbation-consistency-and-confidence-calibration-96937.md>)

Original publisher: [Read original article](<https://arxiv.org/abs/2610.30422>)

Author: Kunkun Zhang, Kehao Wu, Zhitao Chen, Haigen Hu, Qianwei Zhou

Published: 2026-10-23T04:00:00Z

Content type: article

Language: en

Sources: [arXiv: Machine Learning](<https://devfeed.tech/sources/arxiv-machine-learning.md>)

Topics: [bci](<https://devfeed.tech/topics/bci.md>), [Decoding](<https://devfeed.tech/topics/decoding.md>), [Enhancing AI model performance](<https://devfeed.tech/topics/enhancing-ai-model-performance.md>), [Benchmark](<https://devfeed.tech/topics/benchmark.md>)

Tags: [bci](<https://devfeed.tech/tags/bci.md>), [confidence](<https://devfeed.tech/tags/confidence.md>), [consistency](<https://devfeed.tech/tags/consistency.md>), [continuous](<https://devfeed.tech/tags/continuous.md>), [cs-lg](<https://devfeed.tech/tags/cs-lg.md>), [decoding](<https://devfeed.tech/tags/decoding.md>), [distribution](<https://devfeed.tech/tags/distribution.md>), [eeg](<https://devfeed.tech/tags/eeg.md>), [eess-sp](<https://devfeed.tech/tags/eess-sp.md>), [feature](<https://devfeed.tech/tags/feature.md>), [inference](<https://devfeed.tech/tags/inference.md>), [latency](<https://devfeed.tech/tags/latency.md>), [lightweight](<https://devfeed.tech/tags/lightweight.md>), [memory](<https://devfeed.tech/tags/memory.md>), [module](<https://devfeed.tech/tags/module.md>), [noise](<https://devfeed.tech/tags/noise.md>), [online](<https://devfeed.tech/tags/online.md>), [pass](<https://devfeed.tech/tags/pass.md>), [patterns](<https://devfeed.tech/tags/patterns.md>), [random](<https://devfeed.tech/tags/random.md>), [real-time](<https://devfeed.tech/tags/real-time.md>), [source](<https://devfeed.tech/tags/source.md>)

## AI overview

MOPC adapts EEG motor-imagery decoding during inference in a single pass, without source data or offline target-data access. It uses random-mask perturbations to encourage prediction consistency under signal noise and acquisition artifacts, confidence-calibrated reweighting that incorporates feature-space similarity to address unreliable pseudolabels and class imbalance, and a lightweight memory module to regularize updates and limit forgetting. On BCI IV IIb and OpenBMI, the abstract reports improvements over prior methods of 2.22% and 3.67%, respectively, with per-trial adaptation latency of about 40-60 ms. These findings are limited to the two named datasets and the supplied abstract.

## Source excerpt

arXiv:2610.30422v1 Announce Type: new Abstract: Recently, electroencephalography (EEG)-based brain--computer interfaces (BCIs) have gained traction as portable neural measurement systems. However, the practical deployment of these instruments is often hindered by nonstationarity and cross-subject distribution shifts, which lead to significant intersubject inconsistency. Existing adaptation methods remain impractical for real-time measurement scenarios, as they typically require offline access to source or aggregated target data. To address these challenges, this article proposes memory-augmented online test-time adaptation (OTTA) with perturbation consistency and confidence calibration (MOPC), a source-free framework designed to enhance the reliability of BCI instrumentation. MOPC enables the measurement system to update its decoding parameters on the fly during the inference stage, facilitating single-pass adaptation without accessing sensitive source data. We introduce random-mask perturbations to enforce prediction consistency against inherent EEG signal noise and acquisition artifacts. Furthermore, a confidence-calibrated reweighting loss is designed to integrate feature-space similarity, effectively mitigating unreliable pseudolabels and class imbalance during continuous signal acquisition. To ensure system stability and prevent the catastrophic forgetting of established neural patterns, a lightweight memory module is incorporated to regularize parameter updates within a tight latency budget. Evaluated on the BCI IV IIb and OpenBMI datasets, MOPC achieves state-of-the-art performance, outperforming prior methods by 2.22~\% and 3.67~\%, respectively, while keeping the per-trial adaptation latency to approximately 40--60 ms. This study provides a robust, recalibration-free solution for real-time EEG decoding, marking a significant advancement in the precision and usability of practical BCI measurement instruments.