# Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation

DevFeed: [Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation](<https://devfeed.tech/articles/pediatric-ecg-foundation-model-via-adult-to-pediatric-fine-tuning-downstream-tasks-and-clinical-evaluation-120238.md>)

Original publisher: [Read original article](<https://arxiv.org/abs/2611.07717>)

Author: Yu Cao, Haiyan Xu, Xiaohan Li, Jian Yang, Yuqing Feng, Wei Wang, Haomin Li

Published: 2026-11-06T05:00:00Z

Content type: article

Language: en

Sources: [arXiv: Artificial Intelligence](<https://devfeed.tech/sources/arxiv-artificial-intelligence.md>)

Topics: [AI Foundation Models](<https://devfeed.tech/topics/ai-foundation-models.md>), [Fine-tuning](<https://devfeed.tech/topics/fine-tuning.md>), [Machine learning](<https://devfeed.tech/topics/machine-learning.md>)

Tags: [ai](<https://devfeed.tech/tags/ai.md>), [children](<https://devfeed.tech/tags/children.md>), [classification](<https://devfeed.tech/tags/classification.md>), [cs-ai](<https://devfeed.tech/tags/cs-ai.md>), [ecg](<https://devfeed.tech/tags/ecg.md>), [evaluation](<https://devfeed.tech/tags/evaluation.md>), [fine-tuning](<https://devfeed.tech/tags/fine-tuning.md>), [foundation-model](<https://devfeed.tech/tags/foundation-model.md>), [regression](<https://devfeed.tech/tags/regression.md>)

## AI overview

Directly applying an adult ECG foundation model to pediatric ECGs performed poorly (mean AUC 0.8256), while pediatric fine-tuning reached 0.9695, slightly exceeding training from scratch (0.9661) and reaching 0.9079 with 1% of the training data. On 10,999 external ECGs, fine-tuning had a mean AUC of 0.9385 across 30 labels; reported results also included age prediction (MAE 1.12 years) and congenital heart disease classification (AUC 0.9562). In a 100-case evaluation with 17 clinicians, accuracy increased from 56.8% to 65.4% (p < 0.001), with no reported accuracy decline when AI erred. These abstract-level results support pediatric adaptation as more effective than direct transfer; they do not establish broader clinical outcomes.

## Source excerpt

arXiv:2611.07717v1 Announce Type: new Abstract: Pediatric electrocardiogram (ECG) interpretation is complicated by age-dependent electrophysiological changes that limit direct transfer of adult AI models. We asked whether an adult ECG foundation model could be adapted to pediatric ECGs. Using 339,563 12-lead ECGs from 238,189 children, we compared direct application, pediatric fine-tuning, and training from scratch under an identical architecture. Direct transfer was poor (mean AUC 0.8256). Fine-tuning reached 0.9695, above de novo training (0.9661), and attained 0.9079 using only 1% of training data. On 10,999 external ECGs, fine-tuning achieved a mean AUC of 0.9385 across 30 labels. It generalized to age regression (MAE 1.12 years) and congenital heart disease classification (AUC 0.9562). Across 17 clinicians and 100 cases, diagnostic accuracy rose from 56.8% to 65.4% (p < 0.001) and did not decline when AI erred. Adult ECG foundation models require pediatric adaptation; fine-tuning offers a data-efficient route to scalable pediatric ECG AI.