# ReuScope: Auditing Data Reuse and Evaluation Sensitivity in Capsule Vision 2024

DevFeed: [ReuScope: Auditing Data Reuse and Evaluation Sensitivity in Capsule Vision 2024](<https://devfeed.tech/articles/reuscope-auditing-data-reuse-and-evaluation-sensitivity-in-capsule-vision-2024-112114.md>)

Original publisher: [Read original article](<https://arxiv.org/abs/2610.41835>)

Author: Eunseob Choi, Kyeonghun Kim, Hyuk-Jae Lee, Nam-Joon Kim

Published: 2026-11-02T05:00:00Z

Content type: article

Language: en

Sources: [arXiv: Artificial Intelligence](<https://devfeed.tech/sources/arxiv-artificial-intelligence.md>)

Topics: [Machine learning](<https://devfeed.tech/topics/machine-learning.md>), [Data Quality](<https://devfeed.tech/topics/data-quality.md>), [Data science and engineering](<https://devfeed.tech/topics/data-science-and-engineering.md>)

Tags: [auditing](<https://devfeed.tech/tags/auditing.md>), [case-study](<https://devfeed.tech/tags/case-study.md>), [comparison](<https://devfeed.tech/tags/comparison.md>), [cs-ai](<https://devfeed.tech/tags/cs-ai.md>), [cs-cv](<https://devfeed.tech/tags/cs-cv.md>), [data](<https://devfeed.tech/tags/data.md>), [data-relationships](<https://devfeed.tech/tags/data-relationships.md>), [difference-in-differences](<https://devfeed.tech/tags/difference-in-differences.md>), [evaluation](<https://devfeed.tech/tags/evaluation.md>), [experiment](<https://devfeed.tech/tags/experiment.md>), [overlap](<https://devfeed.tech/tags/overlap.md>), [performance](<https://devfeed.tech/tags/performance.md>), [protocol](<https://devfeed.tech/tags/protocol.md>), [reuse](<https://devfeed.tech/tags/reuse.md>), [uncertainty](<https://devfeed.tech/tags/uncertainty.md>), [vision](<https://devfeed.tech/tags/vision.md>)

## AI overview

ReuScope separates evidence of data reuse from performance sensitivity in its Capsule Vision 2024 audit. Byte-identical files cross the public training-validation boundary, and frames from all 41 Kvasir-Capsule recordings appear in both partitions; missing cross-recording patient identifiers prevent counting unique shared patients. Across ten paired seeds, removing Kvasir-Capsule training rows and five other near-match rows lowers public-validation balanced accuracy from 82.5% to 61.2%. On validation rows from other sources, the same fitted models show the opposite result: removal improves balanced accuracy by 1.38 percentage points. The public-validation decline measures sensitivity to source removal, not leakage-induced inflation, and matched controls suggest sample size and class counts alone do not explain it. An exploratory neighbor-removal comparison estimates a -0.355 percentage-point change in true-class probability, while the paired-t accuracy interval spans zero.

## Source excerpt

arXiv:2610.41835v1 Announce Type: new Abstract: We develop ReuScope, a protocol for auditing data reuse and evaluation sensitivity, using Capsule Vision 2024 as a case study. It combines measurements of data relationships with two comparisons: changing the evaluation population while holding predictions fixed, and changing training data while holding evaluation fixed. Byte-identical files cross the public training-validation boundary, and all 41 Kvasir-Capsule recordings that contribute frames occur in both partitions. Shared source recordings establish cross-split overlap; missing cross-recording patient identifiers prevent counting unique shared patients. Across ten paired seeds, removing all training rows attributed to Kvasir-Capsule, plus five rows from other sources flagged as near-matches to it, lowers public-validation balanced accuracy from 82.5% to 61.2%. Evaluating the same fitted models on the validation rows of the other sources reverses the comparison: removal improves balanced accuracy by 1.38 percentage points. The public-validation drop measures sensitivity to source removal, not an amount of leakage-induced inflation. Matched controls show that sample size and class counts alone do not explain the observed score differences. An exploratory experiment removes the training neighbors of validation frames that have close training matches, or equally many distant training rows, and yields a difference-in-differences estimate, relative to matched unflagged frames, of -0.355 percentage points in true-class probability; the paired-t interval for accuracy spans zero. The resulting procedure distinguishes observed reuse from conditional performance sensitivity and specifies the population, class support and uncertainty unit for each conclusion.