# Safety and accuracy diverge across deployment conditions in clinical large language models

DevFeed: [Safety and accuracy diverge across deployment conditions in clinical large language models](<https://devfeed.tech/articles/safety-and-accuracy-diverge-across-deployment-conditions-in-clinical-large-language-models-123128.md>)

Original publisher: [Read original article](<https://arxiv.org/abs/2605.04039>)

Author: Sebastian Wind, Tri-Thien Nguyen, Jeta Sopa, Mahshad Lotfinia, Sebastian Bickelhaup, Michael Uder, Harald K\\"ostler, Gerhard Wellein, Sven Nebelung, Daniel Truhn, Andreas Maier, Soroosh Tayebi Arasteh

Published: 2026-11-09T05:00:00Z

Content type: article

Language: en

Sources: [arXiv: Artificial Intelligence](<https://devfeed.tech/sources/arxiv-artificial-intelligence.md>), [arXiv: Machine Learning](<https://devfeed.tech/sources/arxiv-machine-learning.md>)

Topics: [LLM security](<https://devfeed.tech/topics/llm-security.md>), [LLM evaluation / benchmarking](<https://devfeed.tech/topics/llm-evaluation-benchmarking.md>), [Large Language Model](<https://devfeed.tech/topics/llm.md>), [Retrieval Augmented Generation (RAG)](<https://devfeed.tech/topics/retrieval-augmented-generation-rag.md>), [Uncertainty quantification LLMs](<https://devfeed.tech/topics/uncertainty-quantification-llms.md>)

Tags: [agentic-rag](<https://devfeed.tech/tags/agentic-rag.md>), [cs-ai](<https://devfeed.tech/tags/cs-ai.md>), [cs-cl](<https://devfeed.tech/tags/cs-cl.md>), [cs-lg](<https://devfeed.tech/tags/cs-lg.md>), [deployment](<https://devfeed.tech/tags/deployment.md>), [evaluation](<https://devfeed.tech/tags/evaluation.md>), [inference](<https://devfeed.tech/tags/inference.md>), [language-models](<https://devfeed.tech/tags/language-models.md>), [large-language-models](<https://devfeed.tech/tags/large-language-models.md>), [medicine](<https://devfeed.tech/tags/medicine.md>), [safety](<https://devfeed.tech/tags/safety.md>), [scaling](<https://devfeed.tech/tags/scaling.md>)

## AI overview

In this evaluation, clinical LLM safety depended more on deployment condition than model family and did not consistently improve with accuracy scaling. The researchers tested 34 local models on RadSaFE-200, a 200-question radiology benchmark, across six conditions. Clean clinician-written evidence yielded the strongest joint results: mean accuracy rose from 73.5% to 94.1%, while high-risk errors fell from 12.0% to 2.6% and dangerous overconfidence from 8.0% to 1.6%. Standard and agentic retrieval-augmented generation, max-context prompting, and inference-time compute improved selected metrics but did not match that safety profile. Consequential errors clustered in a small subset of questions. These findings are limited to the described benchmark and deployment conditions.

## Source excerpt

arXiv:2605.04039v2 Announce Type: replace-cross Abstract: Clinical large language models (LLMs) are commonly scaled by increasing model size, context length, retrieval complexity, or inference-time compute, on the assumption that higher accuracy implies safer behavior. In medicine, where a few confident or evidence-contradicting errors can outweigh average performance, this assumption may be incomplete. We introduce Safety-Focused Evaluation of Scaling (SaFE-Scale) and instantiate it on RadSaFE-200, a 200-question text-based radiology multiple-choice benchmark with clinician-defined clean evidence, conflict evidence, and option-level labels for high-risk error, unsafe answer, and evidence contradiction. Thirty-four local LLMs were evaluated across six deployment conditions spanning closed-book, evidence-grounded, standard and agentic retrieval- augmented generation (RAG), and max-context prompting. Clean clinician-written evidence, used as an upper-bound, produced the strongest joint gain, raising mean accuracy from 73.5% to 94.1% and reducing high-risk error from 12.0% to 2.6% and dangerous overconfidence from 8.0% to 1.6%. Standard and agentic RAG, max-context prompting, and inference-time compute improved selected metrics but did not reproduce this safety profile. Clinically, consequential errors concentrated in a small subset of questions, and variance decomposition placed deployment condition above model family on every safety metric. Within this evaluation, clinical LLM safety did not track accuracy scaling but emerged as a deployment-level property.