# Sensitivity-Gated Accumulator Caching for On-Device Learning of Low-Bit Hand Networks

DevFeed: [Sensitivity-Gated Accumulator Caching for On-Device Learning of Low-Bit Hand Networks](<https://devfeed.tech/articles/sensitivity-gated-accumulator-caching-for-on-device-learning-of-low-bit-hand-networks-125294.md>)

Original publisher: [Read original article](<https://arxiv.org/abs/2611.10991>)

Author: Soroor Ghandali, Kanika Mamgain, Manjot Kaur, Akanksha Shukla, Shashira Guntuka

Published: 2026-11-10T05:00:00Z

Content type: article

Language: en

Sources: [arXiv: Machine Learning](<https://devfeed.tech/sources/arxiv-machine-learning.md>)

Topics: [quantization](<https://devfeed.tech/topics/quantization.md>), [On-device AI](<https://devfeed.tech/topics/on-device-ai.md>), [tinyml](<https://devfeed.tech/topics/tinyml.md>)

Tags: [caching](<https://devfeed.tech/tags/caching.md>), [cs-cv](<https://devfeed.tech/tags/cs-cv.md>), [cs-lg](<https://devfeed.tech/tags/cs-lg.md>), [learning](<https://devfeed.tech/tags/learning.md>), [networks](<https://devfeed.tech/tags/networks.md>), [on-device](<https://devfeed.tech/tags/on-device.md>), [on-device-learning](<https://devfeed.tech/tags/on-device-learning.md>), [quantization](<https://devfeed.tech/tags/quantization.md>)

## AI overview

Sensitivity-gated accumulator caching (SGAC) adapts low-bit network weights while keeping residual state only for selected groups. It uses a cache of 8-bit accumulators to collect sub-step updates for groups ranked by Fisher-weighted squared code step, then writes whole steps into the codes; evicted accumulators are flushed by stochastic rounding, while groups without a cache line do not update. The authors report unbiased write-back and, under a local quadratic model, explain that rounding is worthwhile where expected gradients are large relative to curvature. On a 383k-parameter hand-keypoint network, SGAC uses 8.1 state bits per weight and achieves the highest mean accuracy among nine deployed low-bit networks on two simulated cameras. Across twelve ImageNet-C corruptions, it leads seven deployed methods in average clean and corrupted accuracy, with confidence intervals excluding zero, and matches a per-weight 8-bit accumulator using 56% as much state.

## Source excerpt

arXiv:2611.10991v1 Announce Type: cross Abstract: Small hand-tracking networks are deployed as 4- and 8-bit codes, and they should keep adapting to a user's camera after deployment, on the device and within roughly the memory of the model itself. Quantization-aware training cannot do this cheaply, because it keeps a 32-bit master copy of every weight together with its optimizer state, about 96 bits per weight. Training the codes directly with stochastic rounding needs no copy but injects rounding noise at every step, and the methods that remove this noise keep a residual buffer for every weight. We introduce sensitivity-gated accumulator caching (SGAC), which keeps residual state for only a small and changing set of weight groups. A set-associative cache of 8-bit accumulators collects the sub-step updates of the groups with the largest Fisher-weighted squared code step and writes them into the codes as whole steps; an evicted line is flushed by stochastic rounding, and a group without a line does not move until it is admitted. We prove that the write-back is unbiased and show, under a local quadratic model, that rounding a sub-step update costs loss of the same order as the update's own gain, so that rounding pays only where the expected gradient is large relative to the curvature. On a 383k-parameter hand-keypoint network, SGAC trains with 8.1 bits of state per weight. Scored on the 4/8-bit network that the device runs after adaptation, it has the highest mean accuracy of nine deployed low-bit networks on two simulated cameras. On twelve ImageNet-C corruptions it has the highest average of corrupted and clean accuracy of seven deployed methods, ahead of the PEQA-style, ECO-style and direct low-bit baselines with confidence intervals that exclude zero, and it matches an 8-bit accumulator kept for every weight with 56% of that state.