# Smart Humidity Monitor & Alert System with Windows GUI

DevFeed: [Smart Humidity Monitor & Alert System with Windows GUI](<https://devfeed.tech/articles/smart-humidity-monitor-alert-system-with-windows-gui-123801.md>)

Original publisher: [Read original article](<https://blog.adafruit.com/2026/11/09/smart-humidity-monitor-alert-system-with-windows-gui/>)

Author: Anne Barela

Published: 2026-11-09T17:20:15Z

Content type: article

Language: en

Sources: [Adafruit Industries](<https://devfeed.tech/sources/adafruit-industries-makers-hackers-artists-designers-and-engineers.md>)

Topics: [Automation](<https://devfeed.tech/topics/automation.md>), [Windows](<https://devfeed.tech/topics/windows.md>), [GUI](<https://devfeed.tech/topics/gui.md>)

Tags: [air](<https://devfeed.tech/tags/air.md>), [alert](<https://devfeed.tech/tags/alert.md>), [arduino](<https://devfeed.tech/tags/arduino.md>), [arduino-nano](<https://devfeed.tech/tags/arduino-nano.md>), [automation](<https://devfeed.tech/tags/automation.md>), [c](<https://devfeed.tech/tags/c.md>), [controller](<https://devfeed.tech/tags/controller.md>), [dht11](<https://devfeed.tech/tags/dht11.md>), [dry](<https://devfeed.tech/tags/dry.md>), [full](<https://devfeed.tech/tags/full.md>), [gui](<https://devfeed.tech/tags/gui.md>), [hackster](<https://devfeed.tech/tags/hackster.md>), [humidifier](<https://devfeed.tech/tags/humidifier.md>), [monitor](<https://devfeed.tech/tags/monitor.md>), [power](<https://devfeed.tech/tags/power.md>), [projects](<https://devfeed.tech/tags/projects.md>), [relay](<https://devfeed.tech/tags/relay.md>), [room](<https://devfeed.tech/tags/room.md>), [sensor](<https://devfeed.tech/tags/sensor.md>), [sensors](<https://devfeed.tech/tags/sensors.md>), [switch](<https://devfeed.tech/tags/switch.md>), [system](<https://devfeed.tech/tags/system.md>), [time](<https://devfeed.tech/tags/time.md>), [watches](<https://devfeed.tech/tags/watches.md>), [windows](<https://devfeed.tech/tags/windows.md>)

## AI overview

A DHT11 connected to an Arduino Nano (digital pin 5) is sampled every two seconds. Readings below 65% or above 80% humidity trigger a red LED and active buzzer; readings within that range light a green LED and keep the buzzer off. A C# Windows Forms app connects over serial at 9600 baud to display live readings, using Invoke for thread-safe interface updates. The original plan to switch a cool mist humidifier with a 5V relay failed because the humidifier's own touch-button and auto-mode controller did not respond to power cycling, so the project became an alert system.

## Source excerpt

Mousavi posted a humidity monitor on Hackster.io that watches a room and says when it's time to switch on a humidifier. The original plan was full automation: a DHT11 sensor and a 5V relay to power a cool mist humidifier when the air got dry. That didn't work. The humidifier has its own logic controller [...]