# SmartMeterFM: Flow Matching for Smart Meter Data Generation, Imputation, and Super-Resolution Without Retraining

DevFeed: [SmartMeterFM: Flow Matching for Smart Meter Data Generation, Imputation, and Super-Resolution Without Retraining](<https://devfeed.tech/articles/smartmeterfm-flow-matching-for-smart-meter-data-generation-imputation-and-super-resolution-without-retraining-111371.md>)

Original publisher: [Read original article](<https://arxiv.org/abs/2601.21706>)

Author: Nan Lin, Yanbo Wang, Jacco Heres, Peter Palensky, Pedro P. Vergara

Published: 2026-11-02T05:00:00Z

Content type: article

Language: en

Sources: [arXiv: Machine Learning](<https://devfeed.tech/sources/arxiv-machine-learning.md>)

Topics: [AI Models](<https://devfeed.tech/topics/ai-models.md>), [Time-sequences](<https://devfeed.tech/topics/time-sequences.md>), [Data analysis](<https://devfeed.tech/topics/data-analysis.md>)

Tags: [case-study](<https://devfeed.tech/tags/case-study.md>), [conditional](<https://devfeed.tech/tags/conditional.md>), [cs-lg](<https://devfeed.tech/tags/cs-lg.md>), [cs-sy](<https://devfeed.tech/tags/cs-sy.md>), [dataset](<https://devfeed.tech/tags/dataset.md>), [diffusion](<https://devfeed.tech/tags/diffusion.md>), [eess-sy](<https://devfeed.tech/tags/eess-sy.md>), [flow-matching](<https://devfeed.tech/tags/flow-matching.md>), [guidance](<https://devfeed.tech/tags/guidance.md>), [inference](<https://devfeed.tech/tags/inference.md>), [projection](<https://devfeed.tech/tags/projection.md>), [super-resolution](<https://devfeed.tech/tags/super-resolution.md>), [synthetic-data-generation](<https://devfeed.tech/tags/synthetic-data-generation.md>), [temporal](<https://devfeed.tech/tags/temporal.md>), [training](<https://devfeed.tech/tags/training.md>)

## AI overview

SmartMeterFM uses one conditional flow matching model, trained on monthly smart meter profiles at 15-minute resolution, for generation, imputation, and super-resolution without task-specific retraining. Customer and calendar attributes condition training; at inference, projection-based guidance incorporates numerical profile constraints, observed intervals, and coarse measurements. The abstract reports preservation of temporal patterns and extreme values while matching supplied observations. In a large Dutch consumption and photovoltaic case study, it achieved lower mean CRPS than selected task-specific baselines for imputation and 16-fold super-resolution. On a public dataset of 2,400 residential meters, ancestral sampling matched a task-trained diffusion model's imputation CRPS; the default sampler had 4.5% lower super-resolution CRPS and met specified monthly maximum and mean power within 0.01 kW.

## Source excerpt

arXiv:2601.21706v3 Announce Type: replace Abstract: Distribution system operators need realistic load and generation profiles when measurements are unavailable, incomplete, or too coarse for the intended analysis. Training separate models for synthetic data generation, imputation, and super-resolution can duplicate modeling effort as observation requirements change. This paper presents SmartMeterFM, a conditional flow matching model trained once on monthly smart meter profiles at 15 min resolution. Customer and calendar attributes condition the model during training, while numerical profile constraints, observed intervals, and coarse measurements are incorporated through projection-based guidance at inference. The same weights serve all tasks without task-specific retraining and preserve temporal patterns and extreme values while producing profiles consistent with the supplied observations. A large-scale case study using Dutch consumption and photovoltaic generation profiles reports lower mean Continuous Ranked Probability Score (CRPS) than the selected task-specific baselines for imputation and 16-fold super-resolution. On a public dataset of 2,400 residential meters, the same weights match the imputation CRPS of a task-trained diffusion model when sampled ancestrally, attain a 4.5% lower super-resolution CRPS with the default sampler, and meet the specified monthly maximum and mean power within 0.01 kW.