# Towards Field-Deployable Wearable IMU Systems for Occupational Activity Recognition

DevFeed: [Towards Field-Deployable Wearable IMU Systems for Occupational Activity Recognition](<https://devfeed.tech/articles/towards-field-deployable-wearable-imu-systems-for-occupational-activity-recognition-97028.md>)

Original publisher: [Read original article](<https://arxiv.org/abs/2610.31160>)

Author: Ihsan Ul Haq (Centre for Computational Science and Mathematical Modelling, Coventry University, United Kingdom, School of Architecture and Built Environment Deakin University, Australia), James Brusey

Published: 2026-10-23T04:00:00Z

Content type: article

Language: en

Sources: [arXiv: Machine Learning](<https://devfeed.tech/sources/arxiv-machine-learning.md>)

Topics: [Machine learning](<https://devfeed.tech/topics/machine-learning.md>), [ai evaluation](<https://devfeed.tech/topics/ai-evaluation.md>), [Data science and engineering](<https://devfeed.tech/topics/data-science-and-engineering.md>)

Tags: [analysis](<https://devfeed.tech/tags/analysis.md>), [benchmark](<https://devfeed.tech/tags/benchmark.md>), [cs-lg](<https://devfeed.tech/tags/cs-lg.md>), [dataset](<https://devfeed.tech/tags/dataset.md>), [deployment](<https://devfeed.tech/tags/deployment.md>), [evaluation](<https://devfeed.tech/tags/evaluation.md>), [field](<https://devfeed.tech/tags/field.md>), [fusion](<https://devfeed.tech/tags/fusion.md>), [imu](<https://devfeed.tech/tags/imu.md>), [laboratory](<https://devfeed.tech/tags/laboratory.md>), [performance](<https://devfeed.tech/tags/performance.md>), [pilot](<https://devfeed.tech/tags/pilot.md>), [protocol](<https://devfeed.tech/tags/protocol.md>), [real-world](<https://devfeed.tech/tags/real-world.md>), [recognition](<https://devfeed.tech/tags/recognition.md>), [scaling](<https://devfeed.tech/tags/scaling.md>), [sensor](<https://devfeed.tech/tags/sensor.md>), [series](<https://devfeed.tech/tags/series.md>), [wearable](<https://devfeed.tech/tags/wearable.md>), [windows](<https://devfeed.tech/tags/windows.md>), [worker](<https://devfeed.tech/tags/worker.md>)

## AI overview

On the VTT-ConIoT benchmark, high aggregate accuracy can hide substantial differences between workers: in the main 16-class, multi-sensor LOSO configuration, per-subject accuracy ranged from 61.9% to 88.7% (mean 77.5%), despite all data being laboratory-collected. The study reports that sensor fusion and longer windows improve accuracy, standard time-series augmentation yields small consistent gains, and CTGAN augmentation reduces accuracy through a distributional-fidelity problem. In a personalised-calibration pilot, using 30% of a participant's own data recovered 16.8 percentage points for the weakest participants. These results offer configuration evidence toward field deployment, but do not establish performance in the field.

## Source excerpt

arXiv:2610.31160v1 Announce Type: new Abstract: Wearable inertial measurement unit (IMU) systems for construction worker human activity recognition (HAR) routinely report aggregate accuracies above 95 %, rarely under genuine subject-independent (leave-one-subject-out (LOSO)) evaluation, masking the per-individual variance that determines real-world deployment performance. Using the VTT-ConIoT benchmark, we conduct, to our knowledge, the first systematic configuration sensitivity analysis of this dataset: six classifiers across five sensor placements and three window sizes under a single LOSO protocol, a personalised-calibration pilot, and a validated comparison of tabular GAN-based and standard time-series augmentation. Per-subject LOSO accuracy for the main multi-sensor, 16-class configuration ranges from 61.9 % to 88.7 % (mean 77.5 %), a 27 pp spread, though all data are laboratory-collected. Multi-sensor fusion and longer windows both improve accuracy; standard augmentation gives small, consistent gains, while Conditional Tabular GAN (CTGAN) augmentation actively harms accuracy with a demonstrated distributional-fidelity mechanism; and personalised calibration recovers 16.8 pp for the weakest participants from just 30 % of their own data. These findings provide evidence-grounded configuration guidance for scaling occupational body sensor networks towards field deployment