# leading silence

Published articles for leading silence.

This is one page of public article previews, not the complete archive. Follow Next page to continue. Summaries are not the original full articles.

## How a benchmark change produced a faster TTS model

DevFeed: [How a benchmark change produced a faster TTS model](<https://devfeed.tech/articles/how-a-benchmark-change-produced-a-faster-tts-model-81217.md>)

Original publisher: [Read original article](<https://gradium.ai/blog/coval-perceived-ttfa-benchmark>)

Author: Gradium

Published: 2026-09-09T00:00:00Z

Content type: article

Language: en

Sources: [Gradium](<https://devfeed.tech/sources/gradium.md>)

Topics: [Benchmark](<https://devfeed.tech/topics/benchmark.md>), [AI-generated research reports](<https://devfeed.tech/topics/ai-generated-research-reports.md>)

Tags: [ai-benchmarks](<https://devfeed.tech/tags/ai-benchmarks.md>), [benchmark](<https://devfeed.tech/tags/benchmark.md>), [coval-tts-leaderboard](<https://devfeed.tech/tags/coval-tts-leaderboard.md>), [engineering](<https://devfeed.tech/tags/engineering.md>), [leading-silence](<https://devfeed.tech/tags/leading-silence.md>), [license](<https://devfeed.tech/tags/license.md>), [livekit](<https://devfeed.tech/tags/livekit.md>), [perceived-ttfa](<https://devfeed.tech/tags/perceived-ttfa.md>), [text-to-speech-latency](<https://devfeed.tech/tags/text-to-speech-latency.md>), [time-to-first-audio](<https://devfeed.tech/tags/time-to-first-audio.md>), [tts](<https://devfeed.tech/tags/tts.md>), [tts-benchmark](<https://devfeed.tech/tags/tts-benchmark.md>), [tts-benchmark-methodology](<https://devfeed.tech/tags/tts-benchmark-methodology.md>), [voice-agent-latency](<https://devfeed.tech/tags/voice-agent-latency.md>)

### AI overview

Coval changed its text-to-speech benchmark to include leading silence before the first audible sample, increasing Gradium's reported time to first audio despite no model or serving change. The article explains how the metric detects audible onset and why the new results cannot be compared directly with earlier leaderboard rows. Gradium says the measure prompted work on a model with no measured leading silence, which now reports a median TTFA of 214 ms.

### Source excerpt

On June 3, 2026, Gradium's time to first audio on the Coval TTS leaderboard moved from 171.9 ms to 429.6 ms. No model had shipped and no serving infrastructure had changed. What changed was the measurement: Coval had started counting the silence at the start of the stream.